Industrial Power Transformers Manufacturing

Power Transformers

Engineering Excellence

Heavy-Duty Substation & Industrial Power Transformers

URJA Techniques designs and manufactures oil-immersed power transformers up to 10 MVA in the 33 kV voltage class. Engineered to perform reliably under demanding electrical network conditions, our units serve power utility substations, renewable energy parks, oil refineries, chemical plants, and heavy manufacturing facilities globally.

Each unit is tailored to customer technical specifications, offering either On-Load Tap Changers (OLTC) with automatic voltage regulating relays (RTCC) or Off-Circuit Tap Changers (OCTC). Designed and evaluated strictly in accordance with IEC 60076, IS 2026, and ANSI/IEEE standards, our power transformers feature high short-circuit withstand capabilities verified by premier test bodies including CPRI and ERDA.

Key Advantages

Engineered for High Reliability & Long Life

Short-Circuit Proven

Type-tested at independent test laboratories (CPRI & ERDA) for dynamic and thermal short-circuit withstand strength, ensuring structural integrity during network faults.

Low Core & Copper Loss

Constructed with laser-scribed, high-permeability prime CRGO silicon steel laminations with step-lap mitered joints and electrolytic grade copper conductor windings.

Advanced Cooling

Available in ONAN, ONAF, and OFAF configurations with engineered radiator headers and multi-stage cooling control, designed for elevated ambient and tropical environments.

Technical Capabilities

Standard Specifications & Parameters

Power Rating Capacity Up to 10,000 kVA (10 MVA) Three Phase / Single Phase
Voltage Class Primary up to 33 kV (e.g., 33 kV, 22 kV, 11 kV, 6.6 kV) / Secondary as required
Applicable Standards IEC 60076, IS 2026, BS 171, ANSI C57.12, IEEE Standards
Insulating Fluid Mineral Transformer Oil (IS 335 / IEC 60296) or Ester Fluid (FR3 / Synthetic)
Cooling Methods ONAN (Oil Natural Air Natural) / ONAF (Oil Natural Air Forced)
Voltage Regulation / Tapping On-Load Tap Changer (OLTC) with RTCC panel / Off-Circuit Tap Changer (OCTC)
Vector Group Dyn11, Dyn5, Ynd11, YNd1, or as per site network configuration
Frequency 50 Hz / 60 Hz
Standard Protection Fittings Buchholz relay, Magnetic Oil Level Gauge (MOG), OTI/WTI with alarm & trip, Pressure Relief Device (PRD), dehydrating breather
Export Markets Supplied UAE, Saudi Arabia, Oman, Kenya, Nigeria, South Africa, Tanzania, Indonesia, and Australia

Looking for Custom Power Transformer Engineering?

Consult with our transformer design engineers for specialized vector configurations, dual-voltage designs, loss evaluation, and complete technical tenders.

Inquire Now